EN 50310:2016/prA2:2026
EN 50310:2016/prA2:2026
EN 50310:2016/prA2:2026: Telecommunications bonding networks for buildings and other structures

Contents Page

European foreword 3

1 Modifications to the Introduction 4

2 Modifications to Clause 1, Scope 4

3 Modifications to Clause 2, Normative references 5

4 Modifications to Clause 3, Terms, definitions and abbreviations 5

5 Modifications to Clause 5, Overview of bonding networks 5

6 Modifications to 6.1, Assessment of the impact of the telecommunications bonding network on the interconnection of telecommunications equipment 6

7 Modifications to 7.4.1.2, Installation 7

8 Modification to 7.4.2, Telecommunications bonding network connections 7

9 Modifications to 7.5.2.2, Rack bonding conductors (RBC) for impedance control 7

10 Modification to 7.5.3, Internal connections 7

11 Modifications to 7.6.3 — Bonding conductors for impedance control 7

12 Modification to 7.7 — Documentation 7

13 Modifications to 8.2.4.1 — Telecommunications bonding backbone (TBB) 7

14 Modifications to 8.3.1 — Primary bonding busbar (PBB) 8

15 Modifications to 8.3.4 — Telecommunications bonding backbone (TBB) 8

16 Modification to 8.3.7 — Bonds to structural metal 8

17 Modifications to 9.2.2 — Bonding conductors for impedance control 8

18 Modifications to 10.2.2 — TEBC for impedance control 8

19 Modification to 11.2.1.1 — Requirements 8

20 Modifications to 11.3 — Bonding conductors of a mesh bonding network 8

21 Modification to A.3.2 — Requirements 9

22 Modifications to the Bibliography 9

European foreword

This document (EN 50310:2016/prA2:2026) has been prepared by CLC/TC 215 “Electrotechnical aspects of telecommunication equipment.

This document is currently submitted to the Enquiry.

The following dates are proposed:

latest date by which the existence of this document has to be announced at national level

(doa)

dav + 6 months

latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement

(dop)

dav + 12 months

latest date by which the national standards conflicting with this document have to be withdrawn

(dow)

dav + 36 months (to be confirmed or modified when voting)

 

1.0 Modifications to the Introduction

Replace Figure 1 with the following figure:

Replace Table 1 with the following table:

Building design phase

Generic cabling design phase

Specification phase

Installation phase

Operation phase

EN 50310

EN 50173‑2

EN 50173‑3

EN 50173‑4

EN 50173‑5

EN 50173‑6

EN 50173‑10

EN 50173‑20

(these ENs reference general requirements of EN 50173‑1)

EN 50174‑1

EN 50174‑2
EN 50174‑3
EN 50174‑4
EN 50310

EN 50174‑1

Planning phase

EN 50174‑2
EN 50174‑3
EN 50310

2.0 Modifications to Clause 1, Scope

Replace the first paragraph and the list item a) with:

This document specifies requirements and provides recommendations for the design and installation of connections (bonds) between various electrically conductive elements in buildings and other structures, during their construction or refurbishment, in which information or telecommunications technology equipment is intended to be installed in order to:

a) minimise the d.c. and a.c. potential differences in order to reduce the risk of malfunction of that equipment and interconnecting cabling due to electromagnetic disturbance;

3.0 Modifications to Clause 2, Normative references

Replace the references “EN 50174‑2:2009” and “EN 50174‑2:2009/A1:2011” with the following:

“EN 50174‑2:2018, Information technology - Cabling installation - Part 2: Installation planning and practices inside buildings”

4.0 Modifications to Clause 3, Terms, definitions and abbreviations

In 3.1, modify the following terms and definitions and add at the end of the list:

Replace definition 3.1.1 with:

“3.1.1

access provider

operator or another entity providing the means to enable external telecommunications service provision to a subscriber

[SOURCE: EN 50700:2023, 3.1.3]”

Replace definition 3.1.3 with:

“3.1.3

application

system, with its associated transmission and power feeding method that is supported by telecommunications cabling

[SOURCE: EN 50173‑1:2018, 3.1.5]”

In definitions 3.1.7 and 3.1.22 delete the words “an item of”.

Delete term and definition 3.1.9 and renumber the following terms accordingly.

In definition 3.1.13 delete the words “within a local area”

Add, at the end of the list, the following new term and definition:

“3.1.27

bonding network

BN

set of interconnected conductive structures that mitigate electromagnetic interference for electronic systems

Note 1 to entry:   This document describes four general types of bonding network: star, ring, local mesh, and mesh.”

5.0 Modifications to Clause 5, Overview of bonding networks

Add at the end of the clause the following text:

“Bonding networks have multiple types with increasing suitability from star to ring to local mesh to mesh.

Figure 3 shows examples of bonding network types. Requirements and descriptions are detailed in Clause 9 to Clause 11.

See 9.1.1.

See 9.1.2.

See 11.2.1.

Bond connections at all mesh intersections and between mesh and equipment.

a) Star

b) Ring

c) Local mesh

d) Mesh

Figure 3 — Examples of bonding network types

Renumber the following figures and their cross references accordingly.

6.0 Modifications to 6.1, Assessment of the impact of the telecommunications bonding network on the interconnection of telecommunications equipment

Replace the 6th paragraph with

Following this assessment, if there are financial or technical justifications for an implementation other than that of Clause 11, then the bonding networks of Clauses 8, 9 or 10 (as appropriate) should be considered, taking into account the risk of telecommunications disruption. It is recommended that the assessment of the bonding system also considers the necessary operational availability of the telecommunication services and their value added.

Replace the 8th paragraph and Table 2 with

The typical comparative sensitivity of the various types of applications supported to a lack of bonding network performance (d.c. resistance and impedance) is shown in Table 2.

Table 2 — Typical sensitivity of applications to bonding network performance

Applications using

Sensitivity to bonding networking performance

Asymmetric cabling or
symmetric cabling (unbalanced applications)

High

Symmetric cabling
(screened or unscreened with balanced applications)

Optical fibre cabling

Low

7.0 Modifications to 7.4.1.2, Installation

Replace the 2nd paragraph with:

“Telecommunications bonding conductors shall be installed in accordance with the applicable minimum bend radius (installation, operating-static and operating-dynamic). Telecommunications bonding conductors shall not be coiled nor doubled back on themselves.”

Replace the last but one paragraph with:

“Bonding connectors and the fastenings and processes used to connect them to the conductive elements of bonding networks shall be designed to provide and maintain a d.c. contact resistance of ≤100 mΩ.”

8.0 Modification to 7.4.2, Telecommunications bonding network connections

Replace in the last paragraph “(with reference to IEC 60950‑1)” with “(with reference to EN IEC 62368‑1)”

9.0 Modifications to 7.5.2.2, Rack bonding conductors (RBC) for impedance control

In 7.5.2.2.1, amend “n = ROUNDUP(l/6) − 1” to readn = (l/6) rounded down to the nearest integer”

In 7.5.2.2.2, replace “ROUNDUP” with “round up”

10.0 Modification to 7.5.3, Internal connections

In 7.5.3.1, move the last sentence (starting with “Where screened cables are terminated …”.) after the 3rd paragraph and amend the dated reference to read “… EN 50174‑2:2018, 5.3.6.”

Insert a new subclause “7.5.3.2 Recommendations” before the paragraph starting with “The bonding conductors attached…”

Renumber 7.5.3.2 into 7.5.3.3.

In 7.5.3.3, list item b), replace “shall be with “is”.

11.0 Modifications to 7.6.3 — Bonding conductors for impedance control

In 7.6.3.1, amend “n = ROUNDUP(l)−1” to readn = (l /6) rounded down to the nearest integer”

In 7.6.3.2, amend “n = ROUNDUP(2 × l) – 1” to readn = (2 x l) rounded down to the nearest integer”

12.0 Modification to 7.7 — Documentation

Replace the paragraph with:

“In a bonding system network, connections shall be documented in a set of relevant documents (such as technical drawings, layouts, schematics, termination details, schedules and supporting pictures).

Depending on the complexity of the installation, the use of electronic or AIM system compliant to EN 50667 should be considered.”

13.0 Modifications to 8.2.4.1 — Telecommunications bonding backbone (TBB)

In 8.2.4.1.1, amend “n = ROUNDUP(l/6)−1” to readn = (l/6) rounded down to the nearest integer”

In 8.2.4.1.2, Amend “n = ROUNDUP(l/3) − 1” to readn = (l/3) rounded down to the nearest integer”

14.0 Modifications to 8.3.1 — Primary bonding busbar (PBB)

In 8.3.1.1, replace the first paragraph with

“There shall be one PBB associated with each MET in a building. The PBB shall be installed either in the TEF (if an electrical distribution panel for telecommunications equipment is present) or in the space which accommodates a generic cabling building distributor and the associated telecommunications equipment.”

In 8.3.1.2, last paragraph, replace “shall” with “should”

15.0 Modifications to 8.3.4 — Telecommunications bonding backbone (TBB)

Replace the 2nd paragraph with:

“TBB conductors shall be protected from physical and mechanical damage. The TBB conductors should be installed without splices. If splices are unavoidable, there shall be a minimum number of splices. Splices shall be accessible and located in telecommunications spaces.”

16.0 Modification to 8.3.7 — Bonds to structural metal

Replace the 3rd paragraph with:

“Structural metal that is bonded to the MET may be used in place of a TBB or a BBC. Before utilizing structural metal in place of a TBB or a BBC, building plans (including as-built drawings as applicable) and specifications shall be reviewed to verify that the structural metal is electrically continuous and its resistivity complies with, or can be modified to be compliant with the bonding requirements.”

17.0 Modifications to 9.2.2 — Bonding conductors for impedance control

In 9.2.2.1, amend “n = ROUNDUP(l/6)−1” to readn = (l/6) rounded down to the nearest integer”

In 9.2.2.2, amend “n = ROUNDUP(l/3) – 1” to readn = (l/3) rounded down to the nearest integer”

18.0 Modifications to 10.2.2 — TEBC for impedance control

In 10.2.2.1, amend “n = ROUNDUP(l/6)−1” to readn = (l/6) rounded down to the nearest integer”

In 10.2.2.2, amend “n = ROUNDUP(l/3) – 1” to readn = (l/3) rounded down to the nearest integer”

19.0 Modification to 11.2.1.1 — Requirements

Replace the 2nd paragraph with

“The MESH-IBN is typically limited to a restricted area within a building such as in areas of concentration of information or telecommunications technology equipment. The MESH-IBN is not typical but can be utilized for a commercial environment. The MESH-IBN is recognized and sometimes utilized in access provider premises.”

20.0 Modifications to 11.3 — Bonding conductors of a mesh bonding network

In 11.3.1, 3rd paragraph, amend “n = ROUNDUP(l/6)−1” to readn = (l/6) rounded down to the nearest integer”.

In 11.3.2, 1st paragraph, replace “mesh earthing network” with “mesh bonding network”.

In 11.3.2, 2nd paragraph, amend “n = ROUNDUP(l/3) − 1” to readn = (l/3) rounded down to the nearest integer”.

21.0 Modification to A.3.2 — Requirements

In the 1st paragraph, replace “EN 60950‑1 contains a table…” with “EN IEC 62368‑1 contains a table…”

22.0 Modifications to the Bibliography

Add the following references to the list:

EN 50667, Information technology - Automated infrastructure management (AIM) systems - Requirements, data exchange and applications

EN IEC 62368‑1, Audio/video, information and communication technology equipment - Part 1: Safety requirements

Delete the following references from the list:

EN 50346, Information technology - Cabling installation - Testing of installed cabling

EN 60950‑1, Information technology equipment - Safety - Part 1: General requirements (IEC 60950‑1)